Electrical Connection
The oven is designed to be connected to 230-240V~(50Hz) electricity supply.
The oven has an easily accessible terminal block which is marked as follows:
Letter L - Live terminal
Letter N - Neutral terminal
- Earth terminal
CAUTION!
This oven must be earthed!
The cable used to connect the oven to the electrical supply must comply to the
specifications given below.
For UK use only
Connection via Min. size Cable/flex Cable/flex type Fuse
Cooker Control Circuit 2,5 mm² PVC/PVC twin and
earth
min: 15 A
max: 20 A
It is necessary that you install a double pole switch between the oven and the
electricity supply (mains), with a minimum gap of 3 mm between the switch con-
tacts and of a type suitable for the required load in compliance with the current
regulations.
The switch must not break the yellow and green earth cable at any point.
After installation and connecting, the cable must be placed so that it cannot at any
point reach a temperature of more than 50°C above the ambient temperature.
Before the oven is connected, check that the main fuse and the domestic instal-
lation can support the load; and that the power supply is properly earthed.
The manufacturer declines any responsibility should these safety measures
not be carried out.
Installation instructions
CAUTION!
The new appliance may only be installed and connected by a qualified installation
engineer. Please comply with this instruction. If you do not, any damage resulting
is not covered by the warranty.