- ITZAA 19/48 599 38 38-50
5.3.3 \Air flow regulator (damper)
The temperature regulation of the cooler compartment occurs by means of the passage or not of cold air from
the damper, which can have only 2 fixed positions, opened or closed.
The air flow regulator (damper) 1 is located inside the diffuser lamp holder 2.
The damper consists of a door and a stepping motor and it is connected to the electric wiring by means of a 4-
pole connector.
5.3.4 Carbon air filter
The carbon air filter 1 is located inside the door 2 indicated in the figure.
The door must be always closed during the operation of the appliance.