Aeg-Electrolux DM8600-M/A User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
13
Technical Specifications
Dimensions* - extraction version (in cm):
Height 66-112
Dimensions* - recirculation version (in cm):
Height 75,5-122
Maximum absorbed power (W): 210
Motor (W): 160
Lighting (W): 2x20
Length of the cable (cm): 150cm
Electrical connection (V): 220-240
* Width and depth depend on the vapour screen which is installed with the cooker
hood, see page 17
Mounting accessories included
1 allen spanner (for TORX screws).
1 deflector (3 pieces to assemble)
1 chimney support (3 pieces to assemble)
4 metal screws 4 x 8 (to assemble the chimney support)
4 metal screws 3,5 x 9,5 (to affix the deflector to the support)
1 support bracket
5 wood-screws 5 x 45 mm (For brick or solid block installations only)
5 wall plugs Ø 8 mm (For brick or solid block installations only )
4 metal screws 2,9 x 6,5 (for chimney flue mounting)
4 metal screws 4 x 35 (to affix the vapour screen to the cooker hood)
Electrical connection
Safety warnings for the electrician
Before connecting the appliance to the power supply, check that the
voltage indicated on the rating plate corresponds to the mains power
supply available. Appliances fitted with a plug can be connected to
any standard power socket within easy access.
Should it be necessary to provide a fixed connection, the hood must
only be installed by an electrician authorised by the local electricity
board. When installing, an omnipolar disconnector with a distance of
at least 3 mm between contacts must be provided.
Fixed connection of the appliance must only be carried out by an
authorised electrician.