Instructions for the installer
25
10.2.3 Replacing the electric cable
To replace the electric cable, it is necessary to access the terminal board. It is located on the back
of the appliance, at the top left, as shown in the figure.
To replace the cable, proceed as follows:
open the terminal board box;
unscrew the screw
A
that locks the cable;
loosen the screw contacts and replace the cable
with one of the same length that corresponds to the
specifications in the table in section “10.2.1 Electric
power cable section”;
the "
yellow-green
" earth wire must be connected to
the terminal
and must be approximately
20 mm
longer than the line cables;
the neutral "
blue
" wire must be connected to the
terminal marked with the letter
N
;
the live "
brown
" must be connected to the terminal
marked with the letter
L
.
10.3 Power consumption of the ceramic hob
The ceramic hob has different power consumptions
depending on the type of heating element used. The
diagram shows the values of the power consumed.
In the envisaged cases, the first numeric value
refers to the total power, whereas the value that
follows the symbol "
/
" refers to the inside diameter,
with the exception of the central heating element,
whose value that follows "
/
" refers to the outer
diameter.
10.4 Ventilation in rooms with gas appliances
This appliance is not connected to an exhaust device for products of combustion. It must therefore
be installed and connected in compliance with current installation standards. Pay particular
attention to standards applied to room aeration.
This appliance can only be installed in ventilated rooms, according to current standards, so as to
allow, with openings onto external walls or appropriate ducts, for correct natural or forced
ventilation that
permanently and sufficiently
ensures both the air intake necessary for correct
combustion and the expelling of vitiated air.