If one or more defects are visible, do not repair the pipe, but replace it.
When installation is complete, make sure that the seal of each pipe fitting is correct. Use a
soapy solution, not a flame!
Injectors replacement
1. Remove the pan supports.
2. Remove the caps and crowns of the burner.
3. With a socket spanner 7 remove the injectors and replace them with the ones which
are necessary for the type of gas you use (see table in Technical Data section).
4. Assemble the parts, follow the same procedure backwards.
5. Replace the rating plate (it is near the gas supply pipe) with the one for the new type
of gas supply. You can find this plate in the package supplied with the appliance.
If the supply gas pressure is changeable or different from the necessary pressure, you must
fit an applicable pressure adjuster on the gas supply pipe.
Adjustment of minimum level
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the knob.
4. With a thin screwdriver, adjust the by-pass screw position.
1
1 The by-pass screw
If you change from natural gas 20 mbar to liquid gas, fully tighten the by-pass
screw in.
If you change from liquid gas to natural gas 20 mbar, undo the by-pass screw ap-
proximately 1/4 of a turn (1/2 of a turn for Triple Crown burner).
WARNING!
Make sure the flame does not go out when you quickly turn the knob from the maximum
position to the minimum position.
Electrical connection
Ground the appliance according to safety precautions.
Make sure that the rated voltage and type of power on the rating plate agree with the
voltage and the power of the local power supply.