Aeg-Electrolux L87484EFL User Manual Page 25

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 24
DETERGENT DISPENSER
To clean the dispenser:
1
2
1.
Press the lever.
2.
Pull the dispenser out.
3.
Remove the top part of the liquid
additive compartment.
4.
Clean all the parts with water.
5.
Clean the dispenser recess with a
brush.
6.
Put back the dispenser in the re-
cess.
DRAIN PUMP
Regularly examine the drain
pump and make sure that it is
clean.
Clean the pump if:
The appliance does not drain the wa-
ter.
The drum cannot turn.
The appliance makes an unusual
noise because of the blockage of the
drain pump.
The display shows an alarm code be-
cause of the problem with water
drain.
WARNING!
1.
Disconnect the mains plug
from the mains socket.
2.
Do not remove the filter
while the appliance oper-
ates. Do not clean the drain
pump if the water in the ap-
pliance is hot. The water
must be cold before you
clean the drain pump.
ENGLISH