electrolux e:line ovens technical specications 33
Technical specications
model product dimensions
(h x w x d) mm
electrical connection min. fuse
rating
max. power
rating
max. current
rating
EOEM61AS 595 x 595 x 567 230-240v/50Hz 16A 3.1kW 12.9A
EOEE62AS 595 x 595 x 567 230-240v/50Hz 16A 3.1kW 12.9A
EOEE63AS 595 x 595 x 567 230-240v/50Hz 16A 3.1kW 12.9A
EUEE63AS 888 x 595 x 567 230-240v/50Hz 25A 5.3kW 22.1A
EDEE63AS 1081 x 595 x 567 230-240v/50Hz 25A 5.8kW 24.2A
EPEE63AS 595 x 595 x 573 230-240v/50Hz 16A 3.1kW 12.9A
EOEK62AK 595 x 595 x 567 230-240v/50Hz 16A 3.1kW 12.9A
error code description comment x
F01 or 01 Door lock sensor alarm This relates to a door lock
failure which is only associated
with the Pyro product
Check wiring/plugs or
replace door lock
F02 or 02 Door lock actuator alarm
F04 or 04 Oven Probe (PT500) out of
range alarm
This relates to the temperature
sensing probe which may be
out of tolerance, or have open/
short circuit connections
Replace probe
F05 or 05 Oven Probe (PT500) too high
temperature alarm
25 Board Temperature Sensor
(NTC) too high temperature
alarm
This relates to the temperature
of the powerboard and/or the
temperature-sensing element
(NTC) on the powerboard
Cooling fan not working
or replace powerboard
26 Board Temperature Sensor
(NTC) out of range warning
6 Board Temperature Sensor
(NTC) out of range alarm
F08 or 08 Communication alarm This relates to an error in
communication between
the powerboard and the IOI
controller. This can occur if the
IOI controller is connected while
the powerboard is energised
Reset power. (Minimum of
20 sec.) or check or replace
data cable
F09 or 09 Software compatibility code
alarm
This relates to a mismatch
between powerboard rmware
version and the IOI controller
rmware version. Most likely
caused by an un-programmed
powerboard
Replace Powerboard
C1 Telescopic runners tted Only applies to Pyro product Remove both side racks and
re-start pyro cycle
C3 Door open Only applies to Pyro product Close door and restart pyro
cycle
F03 or 03 EEPROM check sum alarm Relates to the controller Replace Controller
F14 or 14 EEPROM compatibility code
alarm
Relates to the controller Replace Controller
Page view 32