AEG-Refrigeration 292 5209
80
VH34-AUK 06.94
Santo 2941i longfresh E-Nr.: 621 370 121 (R12)
Santo 2902i longfresh E-Nr.: 621 371 022 (R134A)
6.2.3.Humidity filter
The air layer described under 6.2.2. together with the two integrated humidity filters enables
air humidity to be adjusted from about 40 to 90% as required and separately for the two
shelves.
Slide bar left - low air humidity; slide bar right - high air humidity.
slide bar upper shelf
slide bar lower shelf
6.2.4.longfresh compensation heater
The longfresh compensation heater (10W) is fitted directly underneath the U-evaporator. It
is integrated and therefore not replaceable!
The longfresh compensation heater serves two functions:
- shortening of defrost process in longfresh compartment (see point 4.1)
- supporting of automatic control and refrigeration technological functions.
(see point 5.2.3. and 5.2.4)
6.3. Magnetic valve
Two types of valves are fitted in series: the monostable Danfoss-3-way valve Type 0904 or
the bistable Elbi-3-way valve. If voltage is applied to the Danfoss-3-way valve, then the
longfresh compartment only is cooled. Switch-over of the Elbi-3-way is by voltage impulses.