- 8 -
DGS-TDS-N 03.08 U. H. / A. B. © Electrolux 599 522 770 EN
Elements temperature controlled: steam element
Elements switched on: cooking fan
cooling fan
light
actuator exhauste
actuator desteam
Temperature: steam element controlled with 2. temp. sensor (offset -23°C)
default 96°C
changeable 50° - 96°C (50-95 step 5 and 96°C)
indication yes
temperature set temp. = sensor + offset BK02
Time: default 30 min.
changeable between 6 min. and dur_max
indication yes DUR (Process time)
5 Min.
Specials: exhaust activated DUR minus 5 min.
desteam activated last 5 min. (without exhaust)
2
Cooling fan speed 1
steam element off last 5 min.
Steam wet
Page view 7