4. Connect the hose to a tap with a 3/4” thread.
Always use the hose supplied with the appliance.
Installation should comply with local water authority
and building regulations requirements. A minimum
water pressure of 0.05 MPa is required for safe
operation of the appliance.
If you cannot make the cold water connection direct
from the rising mains, you may be able to operate the
appliance from your cold water storage system. There should be a minimum verti-
cal distance of between the appliance’s inlet and the bottom of the water storage
tank.
Water-stop device
The inlet hose is provided with a water stop device,
which protects against damage caused by water
leaks in the hose which could develop due to
natural ageing of the hose. This fault is shown by a
red sector in the window “A. Should this occur,
turn the water tap off and refer to your Service
Centre to replace the hose.
Water drainage
This appliance is designed to be permanently plumbed
into your home's drainage system using one of the
following methods.
1. Into a drainage standpipe.
Firstly form a hook in the end of the drain hose using
the “U” piece” supplied.
Place the drain hose into your
standpipe, which should have an
internal diameter of approximately
38mm thus ensuring there is an air
break between the drain hose and
standpipe.
43
Installation
A
352
P1199
U piece
supplied
30 cm (12")
38 mm (11.2)
standpipe
diameter
132962540.qxd 28/07/2008 12.03 Pagina 43