Switch Mode Power Supply AC 7000
Page 17 of 24 0208 BAL, en
11. Technical Data
11.1 General Technical Data
Make current.................................. Rated input current
Required mains protection.............gL 16 A
Curve .............................................IU curve in accordance with DIN
41772 or DIN 41773
Emitted interference to EN 50081-1
- Conducted interference...............to EN 55022 Class "B"
- Emission......................................to EN 55022 Class "B"
Noise immunity to EN 50082-2
- Housing .......................................ESD test to EN 61000-4-2,
6 kV contact, 8 kV air discharge
HF field to EN 61000-4-3,
10 V/m (30 MHz - 1 GHz)
- Power cables...............................Burst test to EN 61000-4-4, 2 kV
Surge test to EN 61000-4-5,
4 kV asymmetrical 2 kV symmetri-
cal
- Control cables .............................Burst test to EN 61000-4-4, 2 kV
Surge test to EN 61000-4-5,
2 kV asymmetrical
Functional extra-low voltage..........with safe isolation at U
A
60 V
DC to VDE 0100 Part 410 11.83
Section. 4.3.2
Safe electrical isolation..................at 110 V DC U
A
220 V DC :
to VDE 0160 5.88 Section 5.6
Dynamic response......................... 3% with sudden load fluctuations
between 10%-90%-10% rated
output current (adjustment time t <
1 ms)
Short circuiting...............................continued short-circuit protected,
1 x rated output current