AEG Electrolux THYRO-A Operations Instructions Page 56

  • Download
  • Add to my manuals
  • Print
  • Page
    / 59
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 55
108 109
In Detail
DEVICE APPLICATION CONDITIONS
Built-in device (VDE0160) EN 50 178
General requirements EN 60146-1-1
Design, vertical installation
Operating conditions EN 60 146-1-1; ch. 2.5
Area of application, industrial CISPR 6
Temperature behaviour EN 60 146-1-1; ch. 2.2
Storage temperature D -25 °C - +55 °C
Transport temperature E -25 °C - +70 °C
Operating temperature better B -10 °C - +35 °C
with forced ventilation
-10 °C - +45 °C with natural air cooling
-10 °C - +55 °C
with reduced type current -2%/°C
Use of the device in UL conditions
up to a maximum ambient
temperature of 40 °C.
Load category 1 EN 60 146-1-1 P.2
Humidity class B EN 50 178 Tab. 7 (EN 60 721)
Overvoltage category III EN 50 178 Tab. 3 (849 V)
Degree of contamination 2 EN 50 178 Tab. 2
Air pressure 900 mbar*; 1000 m above sea level
Degree of protection IP00 EN 60529
Protection class I EN 50178 chap. 3
Air and creepage distances housing / mains potential > 5.5 mm
housing / control pot. > 1 mm
mains volt. / control pot. > 10 mm
mains volt. among each other
2.5 mm
Mechanical shocks EN 50 178 chap. 6.2.1
Test voltage EN 50 178 tab. 18
Tests in acc. with EN 60 146-1-1 4.
EMC emitted interference EN 61000-6-4
Radio interference suppression
Control unit Class A EN 55011; CISPR 11
EMC interference immunity EN 61000-6-2
Compatibility level Class 3 EN 61000-2-4
ESD 8 kV (A) EN 61000-4-2
Electromagnetic fields 10 V/m EN 61000-4-3
Burst main lines 2 kV (A) EN 61000-4-4
control lines 2 kV (A)
Surge main lines 2 kV
control lines asym. EN 61000-4-5
1 kV sym. EN 61000-4-5
0.5 kV
Conducted EN 61000-4-6
Page view 55